Table 9. Observations Of Annual Simulation Results For Las Vegas

Las Vegas, Nevada
Simulation Description Observations Of Results
Reference case (R-28 ceiling, 1:150 vented attic, ducts in attic, no duct leakage, R-19 walls, double glazing)
Sealed R-40 sloped Good for cooling, excellent for heating
White tile, sealed R-28 sloped Excellent for cooling, no difference for heating
Ducts in conditioned space Always good
Sealed R-28 sloped No difference for cooling, very good for heating
White tile Very good for cooling, penalty for heating due to reduced solar heat gain
1:300 Attic vent Very little net difference from 1:150 reference case
Sealed R-40 flat Penalty on cooling, saves on heating, nets essentially the same as reference case
Sealed R-28 flat Not recommended
Duct leak 10% ret 5% sup Never good
Duct leak 15% ret 10% sup Never good